raw · articles · ingested 2026-10-27
One-year performance assessment of a passive house container-based prototype
confidence: high
Source: https://zaguan.unizar.es/record/170329?ln=en
Bibliographic Details
- Authors: Adeline Rezeau, Beatriz Rodriguez-Soria, Miguel Angel Garcia-Garcia
- Journal: Energy and Buildings, Vol. 360, Article 117391
- Year: 2026
- DOI: 10.1016/j.enbuild.2026.117391
- Affiliation: University of Zaragoza
- Project: EU LIFE Zero Energy Mod
Methodology
- One full year of monitored performance data from a passive house container-based prototype
- Located at a military base in Zaragoza, Spain (semi-arid continental climate)
- 20-foot shipping container retrofitted to PASSIVHAUS standard
- Monitored indoor temperature, CO2 levels, humidity, and energy consumption
- Prototype was later dismantled and relocated to the Gabriel de Castilla Antarctic research station
- Comparison baseline: conventional containerized units previously monitored by the same research team
Key Performance Data
- Annual heating and cooling energy: 33.9 kWh/m2/yr
- Reduction vs conventional containers: 87%
- Conventional container baseline: approximately 280 kWh/m2/yr (cited in paper)
- Winter performance: Stable indoor temperatures maintained; adequate ventilation confirmed by CO2 monitoring
- Summer performance: Significant overheating occurred during two heatwave events; cooling is the identified weak point
Relevance to Zomeworks Container Prototype
This study is the closest peer-reviewed analogue to the Zomeworks Double Play container. Key parallels:
- Both use 20ft shipping containers as the structural base
- Both target passive heating and cooling without conventional HVAC
- The Rezeau prototype uses Passivhaus insulation standards; the Zomeworks prototype uses Double Play radiant/mass strategies
Key differences:
- Rezeau uses European Passivhaus methodology (superinsulation + mechanical ventilation with heat recovery)
- Zomeworks uses passive radiative cooling and thermal mass strategies native to Baer’s design tradition
- The 87% reduction figure provides a benchmark for what passive container retrofits can achieve, but the mechanisms differ
Implications for Mass Production
- Container form factor enables factory assembly and transport to site
- The LIFE Zero Energy Mod project frames the work as demonstrating relocatable, modular passive buildings
- No cost data reported in the paper
- Summer overheating remains the primary unsolved problem, which is directly relevant to the Double Play cooling cycle